Abstract

BackgroundThe SARS-CoV-2 (COVID-19) pandemic may accelerate the adoption of digital, decentralized clinical trials. Conceptual recommendations for digitalized and remote clinical studies and technology are available to enable digitalization. Fully remote studies may break down some of the participation barriers in traditional trials. However, they add logistical complexity and offer fewer opportunities to intervene following a technical failure or adverse event.ObjectiveOur group designed an end-to-end digitalized clinical study protocol, using the Food and Drug Administration (FDA)–cleared Current Health (CH) remote monitoring platform to collect symptoms and continuous physiological data of individuals recently infected with COVID-19 in the community. The purpose of this work is to provide a detailed example of an end-to-end digitalized protocol implementation based on conceptual recommendations by describing the study setup in detail, evaluating its performance, and identifying points of success and failure.MethodsPrimary recruitment was via social media and word of mouth. Informed consent was obtained during a virtual appointment, and the CH-monitoring kit was shipped directly to the participants. The wearable continuously recorded pulse rate (PR), respiratory rate (RR), oxygen saturation (SpO2), skin temperature, and step count, while a tablet administered symptom surveys. Data were transmitted in real time to the CH cloud-based platform and displayed in the web-based dashboard, with alerts to the study team if the wearable was not charged or worn. The study duration was up to 30 days. The time to recruit, screen, consent, set up equipment, and collect data was quantified, and advertising engagement was tracked with a web analytics service.ResultsOf 13 different study advertisements, 5 (38.5%) were live on social media at any one time. In total, 38 eligibility forms were completed, and 19 (50%) respondents met the eligibility criteria. Of these, 9 (47.4%) were contactable and 8 (88.9%) provided informed consent. Deployment times ranged from 22 to 110 hours, and participants set up the equipment and started transmitting vital signs within 7.6 (IQR 6.3-10) hours of delivery. The mean wearable adherence was 70% (SD 19%), and the mean daily survey adherence was 88% (SD 21%) for the 8 participants. Vital signs were in normal ranges during study participation, and symptoms decreased over time.ConclusionsEvaluation of clinical study implementation is important to capture what works and what might need to be modified. A well-calibrated approach to online advertising and enrollment can remove barriers to recruitment and lower costs but remains the most challenging part of research. Equipment was effectively and promptly shipped to participants and removed the risk of illness transmission associated with in-person encounters during a pandemic. Wearable technology incorporating continuous, clinical-grade monitoring offered an unprecedented level of detail and ecological validity. However, study planning, relationship building, and troubleshooting are more complex in the remote setting. The relevance of a study to potential participants remains key to its success.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call