Abstract
Cord blood (CB) banks and transplantation centers routinely use various assays to measure the number and quality of hematopoietic stem and progenitor cells (HSPC) in hematopoietic cell samples before or after cryopreservation and/or transplantation. Such assays, to measure colony-forming units (CFU) and CD34+/ALDHbright cells, for example, are typically performed on small samples, such as attached segments from frozen CB units. Unfortunately, the accuracy and reliability of these assays are highly sensitive to the presence of contaminating red blood cells (RBCs) in the sample. Current methods for depleting RBCs for downstream analysis include sedimentation by gravity or by centrifugation through density gradient solutions, and hemolysis using ammonium chloride. These procedures are, however, time consuming and may be associated with reduced yield of HSPCs. To address these issues, we have developed a simple and rapid immunomagnetic method (ErythroClear) for depleting RBCs in fresh and thawed CB. RBCs in small (≤100 µL) CB samples are labeled with anti-Glycophorin-A (GlyA) antibodies immobilized on magnetic particles, and removed by magnetic separation. The method allows the handling of multiple samples at one time and takes only 2 minutes per sample. Compared to sedimentation methods using either HetaSep or PrepaCyte, which take 20 minutes per sample, ErythroClear is significantly more effective in depleting RBCs from CB, producing a final purity of 78% GlyAB-CD45+ cells compared to 11% with HetaSep and 9% with PrepaCyte (paired t-test, p<2.9x10-9 and p<3.6x10-9 respectively; n=8). To determine the effect of ErythroClear on the frequency of progenitors, CD34+/ALDHbright cells and CFUs were enumerated in CB samples before and after RBC depletion. The frequencies of CD34+, ALDHbright, and CD34+ALDHbright progenitors in fresh CB remained essentially unchanged following RBC depletion (p=0.75; n=6). Similarly, the frequency of CFUs measured by colony formation in MethoCult H4434 medium was not significantly altered after RBC depletion of fresh (p=0.16; n=11) and previously frozen CB (p=0.21; n=10) samples. RBC depletion using ErythroClear facilitated accurate counting of colonies using STEMvision, an imaging system for automated identification, classification, and enumeration of CFU assays of human blood or bone marrow cells. While automated colony counts differed significantly from manual counts for CFU assays with a high background of RBCs (p<0.02 for frozen-thawed CB [n=10]; p<0.01 for fresh CB [n=11]), very similar CFU numbers were obtained with both colony counting methods for samples in which RBCs were removed using ErythroClear (p=0.32 for thawed CB [n=10]; p=0.24 for fresh CB [n=11]). Taken together, these findings demonstrate that RBCs can be effectively removed from small CB samples by immunomagnetic removal of GlyA+ cells without affecting the frequency of HSPCs, and highlight the importance of depleting RBCs to ensure accurate and reliable enumeration of progenitors in CB samples. DisclosuresLam:STEMCELL Technologies Inc.: Employment. Wognum:STEMCELL Technologies Inc.: Employment. Thomas:STEMCELL Technologies Inc.: Employment. Eaves:STEMCELL Technologies Inc.: CEO and Owner Other. Szilvassy:STEMCELL Technologies Inc.: Employment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.