Abstract
Advanced applications of parametric X-ray radiation (PXR) such as energy-dispersive X-ray absorption fine structure (DXAFS) analysis and phase-contrast imaging have been developed at the Laboratory for Electron Beam Research and Application (LEBRA) of Nihon University. To improve the electron beam quality and geometrical stability of the target crystal, the cooling-water system for the linac and the PXR target was replaced with a new one capable of more precise control. As a result, the reliability of the experimental data in PXR applications, especially in X-ray imaging, has improved. The effect of the electron beam focusing on the target crystal was also investigated. The results of X-ray imaging with a long propagation distance and measurement of the time-structure of the PXR intensity suggest that the correlation between the electron beam profile and the X-ray coherence is rather complicated. It is possible that incident electrons cause some deformation of the target crystal, becoming the dominant factor restricting the quality of intense PXR.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.