Abstract
The aim of the research was to evaluate an influence of floating floor construction specimen size on weighted reduction in impact sound pressure level ΔLW. The large size (area ≥ 10 m2) specimens should be used according to LST EN ISO 10140 series standards. The problem is that produce large specimens is expensive and time-consuming process. So more rapid and cheaper way is to use smaller size (area < 10 m2) specimens and perform measurements in real buildings with similar test conditions as in laboratory. For evaluation of the specimen size influence on reduction in impact sound pressure level ΔLW value sand/cement screed area discreetly was reduced from 13.4 m2 down to 0.5 m2. The test results showed strong dependence of reduction in weighted impact sound pressure level from specimen size. Relying on the test data it was derived relationship which could be applied for the correction of the determined ΔLW values when smaller size specimens (area < 10 m2) of floating floor constructions are used.DOI: http://dx.doi.org/10.5755/j01.ms.18.1.1350
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.