Abstract

The feasibility of using a cylindrical denuder tube for sampling gaseous ammonia, followed by detection with a piezoelectric quartz crystal, was investigated. Gaseous ammonia was sampled with a tungsten oxide-coated cylindrical denuder tube and then thermally desorbed onto a piezoelectric quartz crystal coated with pyridoxine hydrochloride–Antarox CO-880. A linear calibration graph of peak area response versus ammonia concentration sampled was obtained for ammonia concentrations between 3.1 and 8.2 µg l–1. A concentration of 29 ng l–1 of ammonia in air was detected with a signal-to-background ratio of 14:1 by achieving an enrichment ratio of 900 with the tungsten oxide denuder tube.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.