Abstract

We have developed a novel technique of utilizing a stainless steel meshwork mask during treatment of dentin with the Er,Cr:YSGG laser. It is the purpose of this study to observe the surface modifications produced by this method. Many techniques have been developed to facilitate bonding of various materials to dentin. However, an optimal bond has not yet been achieved. Four teeth ground to dentin were randomly assigned to two groups. Group 1: Er,Cr:YSGG laser treatment; and Group 2: laser treatment while a 100 μm aperture stainless steel mesh was situated over the dentinal surface. Group 1 samples appeared rugged but relatively flat. Group 2 samples presented a surface with uniformly aligned craters ∼100 μm wide, 150 μm deep. Masking the dentinal surface with a stainless steel mesh during laser irradiation produces a surface texture that appears to facilitate mechanical retention.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.