Abstract

Two dense nonaqueous phase liquid (DNAPL) tracer tests were carried out in a shallow aquifer north of Fort Worth, TX. i-Propanol was used as the nonpartitioning tracer: n-hexanol and n-octanol were the partitioning tracers. Field data, mathematical modeling, the results of column tests, and field tracer tests with NaCl were used in designing the DNAPL tracer tests. The results indicated the presence of DNAPL at both sites tested; semi-quantitative estimates of the amounts of DNAPL present were obtained by mathematical modeling. Interpretation was complicated by heterogeneity of the aquifer and mass transport effects.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.