Abstract

We propose a technique using Dempster–Shafer fusion based on a deep Boltzmann machine to classify and estimate systolic blood pressure and diastolic blood pressure categories using oscillometric blood pressure measurements. The deep Boltzmann machine is a state-of-the-art technology in which multiple restricted Boltzmann machines are accumulated. Unlike deep belief networks, each unit in the middle layer of the deep Boltzmann machine obtain information up and down to prevent uncertainty at the inference step. Dempster–Shafer fusion can be incorporated to enable combined independent estimation of the observations, and a confidence increase for a given deep Boltzmann machine estimate can be clearly observed. Our work provides an accurate blood pressure estimate, a blood pressure category with upper and lower bounds, and a solution that can reduce estimation uncertainty. This study is one of the first to use deep Boltzmann machine-based Dempster–Shafer fusion to classify and estimate blood pressure.

Highlights

  • Most medical offices, hospitals, and home monitoring devices use an oscillometric technique to measure blood pressure (BP) because maintaining a healthy BP is critical to living a long healthy life

  • The maximum amplitude (MAA) using a fixed ratio is insufficient for estimating the BP since the proportion of these fixed characteristics significantly varies according to the rhythm of the heart, movement artifacts, and cuff size [1,2], which leads to uncertainties of the BP in practice in the oscillometric BP measurements [3,4,5]

  • This study was confirmed by a research ethical committee of the institution, and every volunteer signed an informed consent rule prior to measurements according to the BP measurement protocol of the institutional research ethical board

Read more

Summary

Introduction

Hospitals, and home monitoring devices use an oscillometric technique to measure blood pressure (BP) because maintaining a healthy BP is critical to living a long healthy life. The algorithm of maximum amplitude (MAA) is predominantly utilized to estimate the BP mean by monitoring the cuff pressure in the maximum oscillation. The MAA using a fixed ratio is insufficient for estimating the BP since the proportion of these fixed characteristics significantly varies according to the rhythm of the heart, movement artifacts, and cuff size [1,2], which leads to uncertainties of the BP in practice in the oscillometric BP measurements [3,4,5]. A simple cuffless technique based on ECG using machine learning was developed by Matsumura et al [7]

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call