Abstract

The precision by which an electron spin polarization measurement can be made using a noble-gas polarimeter depends directly on the accuracy of a light-polarization measurement. Since the electron-noble gas collisions occur in a vacuum chamber and the optical polarimeter is generally outside the chamber, this work examines the effect the vacuum window has on the perceived optical polarization. A model light source, lens system, and optical polarimeter are used that approximate the situation found in a typical atomic physics experiment. It was demonstrated that a pressure difference of 1 atm on a lens will alter the perceived polarization by as much as 0.05% with typical borosilicate (BK) lenses. This effect was demonstrated to scale with the thickness of the lens used and changes signs when the direction of the stress is reversed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.