Abstract

Lens focused proton radiograph on thin objects is demonstrated using an 11-MeV proton cyclotron at China Academy of Engineering Physics. The proton beam exiting from the tested objects is focused onto the image plane by a magnetic lens system mitigating image blur caused by multiple Coulomb scattering. Both simulations and experiments show that clear images can be obtained with a lens system for the objects with thickness up to 2.7 × 10-2 g/cm2 and the error for the areal density measurement is measured to be less than 2.3%. For the objects with thickness between 2.7 × 10-3 g/cm2 and 2.7 × 10-2 g/cm2, 100-200 μm of spatial resolution is achieved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.