Abstract

We have designed and tested a set of five miniature nested magnetic shields constructed of high-permeability material, with external volumes for the individual shielding layers ranging from 0.01 to 2.5 cm(3). We present measurements of the longitudinal and transverse shielding factors (the ratio of external to internal magnetic field) of both individual shields and combinations of up to three layers. The largest shielding factor measured was 6 x 10(6) for a nested set of three shields, and from our results we predict a shielding factor of up to 1 x 10(13) when all five shields are used. Two different techniques were used to measure the internal field: a chip-scale atomic magnetometer and a commercially available magnetoresistive sensor. Measurements with the two methods were in good agreement.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call