Abstract

For design purposes of the blower power requirements during startup of a spouting bed process, knowledge of the maximum pressure drop across a spouting bed at the onset of spouting is required. A survey of the literature for this information lead to only a few correlations which required information from a spouting bed test to be applicable. Therefore, an experimental investigation of this pressure drop and its associated superficial gas velocity in a flat based spouted bed operating with and without fluidization has been conducted. Measurements were performed using a 10 cm cylindrical bed with different static bed heights and two Geldard group B particles (Al2O3 and HDPE). The results show that the taller static bed height creates a larger maximum pressure drop across the bed, as expected. The maximum pressure drop also increases with increasing fluidized gas velocity. The evolution of maximum pressure drop and its velocity were evaluated and a correlation for the maximum pressure drop and its corresponding velocity for spouted and spouted fluid beds were obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.