Abstract

An analytic expression is obtained for the point-function demagnetization tensor of the uniformly magnetized equilateral triangular prism element. This result can be used to improve the precision in 3D finite element micromagnetic models, especially for complex boundary geometric shapes. The corresponding magnetometric demagnetization tensors and demagnetization factors are calculated with the expression. The demagnetization field is discussed at various aspect ratios with magnetization perpendicular to the triangle plane.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.