Abstract

The potential is investigated of FIB lithography for implantation delta-doping in order to produce desired arrangements of quantum wires and dots. Both raster and vector scanning are considered. The results are briefly reported of molecular-dynamics and Monte Carlo (SRIM′2003) computations concerned with the scattering of low-energy Al and Sb ions from a monocrystalline-semiconductor surface. It is concluded that the ion energy should be taken within the range 100–300 eV if implantation depths of 1–5 nm are required. A formalism is derived for evaluating the ultimate resolution and the processing time of FIB implanters that use a Gaussian or a vector-scanned variable shaped beam. It is noted that the formalism can be modified to apply to IPL implanters. It is shown that an FIB implanter with an electrostatic objective can provide a lateral resolution better than 20 nm. It is also demonstrated that using a vector-scanned variable shaped beam enables one to create an experimental quantum register containing up to 106 qubits.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.