Abstract

Propagation of an axial crack has been characterized by means of the Pin-Loading Tension (PLT) test. The same experimental arrangement is used for the Delayed Hydrogen Cracking (DHC) and for the J-integral measurements. The DHC tests are performed under variable temperature and/or load conditions simulating a variable PCMI. Tests have been performed in air on unirradiated SRA Zircaloy-4 tubing and irradiated BWR Zircaloy-2 cladding containing from 30–350 ppm of hydrogen. Variable loading facilitates DHC: in the experiment at 300°C a crack velocity as high as 9.3∙10-7 m/s (80 mm/day) has been observed for irradiated cladding. V-K curves or diagrams of DHC crack velocity, V, as a function of stress-intensity factor, K, are suggested for different BWR claddings. Despite a limited amount of tests, the V-K curves appear to depend on the type of cladding. DHC does occur at much lower stress intensities compared to the Kc converted from the J0.2 values, confirming DHC to be the dominating secondary failure crack propagation mechanism in BWR cladding.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.