Abstract
We present a previously unreported complication following the treatment of a patient with two small, wide-necked, posterior communicating artery aneurysms. Endovascular embolization of one aneurysm was performed using a stent-assisted technique. Follow-up angiography 5 months later revealed that a coil had escaped the confinement of the stent and migrated distally without occluding any arterial branches or causing symptoms. This case report demonstrates that although a rare occurrence, a coil can break loose from the stent. We discuss the potential mechanisms of this phenomenon and review the literature on stent-assisted aneurysm coiling in order to raise awareness of this event when embolizing small, wide-necked aneurysms with a stent-assisted technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.