Abstract

A printed circuit board with attached components has been subjected to corona discharges for 200 h at a pressure of 8.66 Pa. The preliminary investigations indicate that: (1) High altitude corona discharges produce visible surface degradation on electronic circuit boards and mounted components. (2) The deterioration is most pronounced in the regions where the electric field is greatest. (3) The solder coating has been removed in localized areas of the interconnecting paths and the underlying copper is now exposed. (4) The circuit board becomes covered with a white dust, the composition of which is still unknown. (5) The deterioration increases with increased exposure up to 200 h, the maximum exposure time considered here.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.