Results are presented showing the radiation response of FOXFET (field-oxide field effect transistor) biased AC-coupled microstrip detectors and related test patterns to be used in the CDF microvertex detector. The radiation tolerance of detectors to gamma and proton irradiation has been tested, and the radiation induced variations of the DC electrical parameters have been analyzed. The long-term post-irradiation behavior of detector characteristics has been studied, and the relevant room-temperature annealing phenomena have been considered. The main radiation damage effects after gamma or proton irradiation of FOXFET biased microstrip detectors consist of an increase of the total leakage current, while both the detector dynamic resistance and FOXFET switching voltage decrease. No radiation-induced variation of the strip self bias Vso is measured up to 1 Mrad. The above variations are due to the generation of Si/SiO/sub 2/ interface traps and positive charge accumulation in the oxide film, as confirmed by C-V measurements on MOS capacitors. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.