Abstract

Tests on instrumentation amplifiers exposed to neutron radiation have been done. The tested devices were commercial instrumentation amplifiers or designed with rad-tol commercial operational amplifiers. The results show changes in frequency behavior, gain, offset voltage, output saturation voltages, and quiescent current. The radiation tolerance is bigger in amplifiers with JFET input stage or with large frequency bandwidth and is smaller if the amplifier has been designed for reducing the power consumption. The IAs built with OPAMPs have a higher tolerance than the commercial ones, but they have disadvantages: high temperature influence, low CMRR, etc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.