Abstract
The degradation at the glass fiber/matrix interface through molecular dynamics simulations in hygrothermal environment is investigated. The glass fiber reinforced polymer composite has been modeled using a cross-linked epoxy matrix and amorphous silica substrate. The degradation mechanism in hygrothermal environment is indicated through the reduction of decreased adhesion energy and the weakened intermolecular interactions with the consideration of hydration bond. Furthermore, softened epoxy molecules in hygrothermal conditioning possess a lower density near the fiber surface, which inhabits the stress transfer between fiber and matrix, eventually leading to the deteriorated interfacial adhesion. Our simulation results echo with the experimental measurements, which can be further calibrated and utilized as inputs in micromechanical models to bridge the gap between the macroscopic and microscopic behavior of civil infrastructures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.