Abstract

Practical lithium-ion battery systems require parallelisation of tens to hundreds of cells, however understanding of how pack-level thermal gradients influence lifetime performance remains a research gap. Here we present an experimental study of surface cooled parallel-string battery packs (temperature range 20–45 °C), and identify two main operational modes; convergent degradation with homogeneous temperatures, and (the more detrimental) divergent degradation driven by thermal gradients. We attribute the divergent case to the, often overlooked, cathode impedance growth. This was negatively correlated with temperature and can cause positive feedback where the impedance of cells in parallel diverge over time; increasing heterogeneous current and state-of-charge distributions. These conclusions are supported by current distribution measurements, decoupled impedance measurements and degradation mode analysis. From this, mechanistic explanations are proposed, alongside a publicly available aging dataset, which highlights the critical role of capturing cathode degradation in parallel-connected batteries; a key insight for battery pack developers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.