Abstract
We report here on the bio-polymeric composite coatings deposition for medical applications, demanding adjustable biodegradability, by the Matrix Assisted Pulsed Laser Evaporation, a sterile laser tool technology, tested for degradation, wettability and bio-compatibility preservation.The specific FTIR bands of both materials indicated stoichiometric deposition of composite coatings, and meanwhile suggested the predominant presence of amorphous SF phase, as also validated by XRD, with low intensity maxima emerging from the amorphous matrix. Concerning the PSADT component, XRD clearly evidenced its specific crystalline contribution.The degradation behaviour in simulated body fluid at 37 °C in dynamic regime was studied as first step of applicability in potential sustained controlled release applications (and/or degradable implanted electronics). Weighing measurements of degraded samples confirmed slower degradation tendency with increasing initial PSADT amount. They also revealed approximately zero order SBF-degradation for 1:1 SF-PSADT ratio. The in vitro assays showed uniform spreading of human mesenchymal stem cells on all synthesized coatings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.