Abstract

Quantitative depth estimation, along with enhanced defect detectability, is of utmost importance for subsurface analysis in thermal wave imaging for a variety of applications. However, the size and the depth of the subsurface anomalies influence this quantitative analysis due to the non-consideration of back reflection from the defect boundary in addition to three-dimensional scattering effects. This study explores an experimental validation of an analytical model for quantitative depth analysis of subsurface anomalies in thermal wave detection and ranging using quadratic frequency-modulated stimulation with pulse compression based signal processing approach and presents the depth resolution feature by considering the back reflection at the defect boundary. It also presents a study on the influence of the size of the anomaly and bandwidth of the stimulation on quantitative depth prediction using the experimentation carried over a carbon fibre reinforced plastic and mild steel specimen with artificial flat-bottom holes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.