Abstract

This paper reports an experimental investigation of deep isotropic etching in HF:HNO3:CH3COOH solution for the fabrication of large microcavities in a silicon wafer. The effects of different practical parameters, e.g., back protective layer, etch window diameter and agitation method, are evaluated experimentally and then discussed. Results show that, for the conditions used, the back protective layer has little influence on the etched depth. Experimental etched profiles are in agreement with the mathematical model of Kuiken's assuming a purely diffusion-controlled etching. Vertical anisotropy and asymmetry of etched profiles were observed. A 100 µm deep hemispherical microcavity was obtained for a 60 min etching with magnetic agitation at room temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.