Abstract
Prompt and accurate diagnosis of arteritic anterior ischemic optic neuropathy (AAION) from giant cell arteritis and other systemic vasculitis can contribute to preventing irreversible vision loss from these conditions. Its clinical distinction from nonarteritic anterior ischemic optic neuropathy (NAION) can be challenging, especially when systemic symptoms are lacking or laboratory markers of the disease are not reliable. To develop, train, and test a deep learning system (DLS) to discriminate AAION from NAION on color fundus images during the acute phase. This was an international study including color fundus images of 961 eyes of 802 patients with confirmed AAION and NAION. Training was performed using images from 21 expert neuro-ophthalmology centers in 16 countries, while external testing was performed in a cohort from 5 expert neuro-ophthalmology centers in the US and Europe. Data for training and external testing were collected from August 2018 to January 2023. A mix of deidentified images of 2 fields of view (optic disc centered and macula centered) were used. For training and internal validation, images were from 16 fundus camera models with fields of 30° to 55°. For external testing, images were from 5 fundus cameras with fields of 30° to 50°. Data were analyzed from January 2023 to January 2024. The performance of the DLS was measured using area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy. In the training and validation sets, 374 (54.9%) of patients were female, 301 (44.2%) were male, and 6 (0.9%) were of unknown sex; the median (range) age was 66 (23-96) years. When tested on the external dataset including 121 patients (35 [28.9%] female, 44 [36.4%] male, and 42 [34.7%] of unknown sex; median [range] age, 69 [37-89] years), the DLS achieved an AUC of 0.97 (95% CI, 0.95-0.99), a sensitivity of 91.1% (95% CI, 85.2-96.9), a specificity of 93.4% (95% CI, 91.1-98.2), and an accuracy of 92.6% (95% CI, 90.5-96.6). The accuracy of the 2 experts for classification of the same dataset was 74.3% (95% CI, 66.7-81.9) and 81.6% (95% CI, 74.8-88.4), respectively. A DLS showing disease-specific averaged class-activation maps had greater than 90% accuracy at discriminating between acute AAION from NAION on color fundus images, at the eye level, without any clinical or biomarker information. A DLS that identifies AAION could improve clinical decision-making, potentially reducing the risk of misdiagnosis and improving patient outcomes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.