Abstract

Infarct size (IS) is the most robust end point for evaluating the success of preclinical studies on cardioprotection. The gold standard for IS quantification in ischemia/reperfusion (I/R) experiments is triphenyl tetrazolium chloride (TTC) staining, typically done manually. This study aimed to determine if automation through deep learning segmentation is a time-saving and valid alternative to standard IS quantification. High-resolution images from TTC-stained, macroscopic heart slices were retrospectively collected from pig experiments (n = 390) with I/R without/with cardioprotection to cover a wide IS range. Existing IS data from pig experiments, quantified using a standard method of manual and subsequent digital labeling of film-scan annotations, were used as reference. To automate the evaluation process with the aim to be more objective and save time, a deep learning pipeline was implemented; the collected images (n = 3869) were pre-processed by cropping and labeled (image annotations). To ensure their usability as training data for a deep learning segmentation model, IS was quantified from image annotations and compared to IS quantified using the existing film-scan annotations. A supervised deep learning segmentation model based on dynamic U-Net architecture was developed and trained. The evaluation of the trained model was performed by fivefold cross-validation (n = 220 experiments) and testing on an independent test set (n = 170 experiments). Performance metrics (Dice similarity coefficient [DSC], pixel accuracy [ACC], average precision [mAP]) were calculated. IS was then quantified from predictions and compared to IS quantified from image annotations (linear regression, Pearson's r; analysis of covariance; Bland-Altman plots). Performance metrics near 1 indicated a strong model performance on cross-validated data (DSC: 0.90, ACC: 0.98, mAP: 0.90) and on the test set data (DSC: 0.89, ACC: 0.98, mAP: 0.93). IS quantified from predictions correlated well with IS quantified from image annotations in all data sets (cross-validation: r = 0.98; test data set: r = 0.95) and analysis of covariance identified no significant differences. The model reduced the IS quantification time per experiment from approximately 90min to 20s. The model was further tested on a preliminary test set from experiments in isolated, saline-perfused rat hearts with regional I/Rwithout/with cardioprotection (n = 27). There was also no significant difference in IS between image annotations and predictions, but the performance on the test set data from rat hearts was lower (DSC: 0.66, ACC: 0.91, mAP: 0.65). IS quantification using a deep learning segmentation model is a valid and time-efficient alternative to manual and subsequent digital labeling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.