Abstract
Dual-energy CT with virtual noncalcium (VNCa) images allows the evaluation of focal intramedullary bone marrow involvement in patients with multiple myeloma. However, current commercial VNCa techniques suffer from excessive image noise and artifacts due to material decomposition used in synthesizing VNCa images. In this work, we aim to improve VNCa image quality for the assessment of focal multiple myeloma, using an Artificial intelligence based Generalizable Algorithm for mulTi-Energy CT (AGATE) method. AGATE method used a custom dual-task convolutional neural network (CNN) that concurrently carries out material classification and quantification. The material classification task provided an auxiliary regularization to the material quantification task. CNN parameters were optimized using custom loss functions that involved cross-entropy, physics-informed constraints, structural redundancy in spectral and material images, and texture information in spectral images. For training data, CT phantoms (diameters 30 to 45cm)withtissue-mimicking inserts were scanned on a third generation dual-source CT system. Scans were performed at routine dose and half of the routine dose. Small image patches (i.e., 40 × 40 pixels) of tissue-mimicking inserts with known basis material densities were extracted for training samples. Numerically simulated insert materials with various shapes increased diversity of training samples. Generalizability of AGATE was evaluated using CT images from phantoms and patients. In phantoms, material decomposition accuracy was estimated using mean-absolute-percent-error (MAPE), using physical inserts that were not used during the training. Noise power spectrum (NPS) and modulation transfer function (MTF) were compared across phantom sizes and radiation dose levels. Five patients with multiple myeloma underwent dual-energy CT, with VNCa images generated using a commercial method and AGATE. Two fellowship-trained musculoskeletal radiologists reviewed the VNCa images (commercial and AGATE) side-by-side using a dual-monitor display, blinded to VNCa type, rating the image quality for focal multiple myeloma lesion visualization using a 5-level Likert comparison scale (-2=worse visualization and diagnostic confidence, -1=worse visualization but equivalent diagnostic confidence, 0=equivalent visualization and diagnostic confidence, 1=improved visualization but equivalent diagnostic confidence, 2=improved visualization and diagnostic confidence). A post hoc assignment of comparison ratings was performed to rank AGATE images in comparison to commercial ones. AGATE demonstrated consistent material quantification accuracy across phantom sizes and radiation dose levels, with MAPE ranging from 0.7% to 4.4% across all testing materials. Compared to commercial VNCa images, the AGATE-synthesized VNCa images yielded considerably lower image noise (50-77% noise reduction) without compromising noise texture or spatial resolution across different phantom sizes and two radiation doses. AGATE VNCa images had markedly reduced area under NPS curves and maintained NPS peak frequency (0.7 lp/cm to 1.0 lp/cm), with similar MTF curves (50% MTF at 3.0 lp/cm). In patients, AGATE demonstrated reduced image noise and artifacts with improved delineation of focal multiple myeloma lesions (all readers comparison scores indicating improved overall diagnostic image quality [scores 1 or 2]). AGATE demonstrated reduced noise and artifacts in VNCa images and ability to improve visualization of bone marrow lesions for assessing multiple myeloma.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.