Abstract

<h3>Purpose/Objective(s)</h3> In existing MR-guided on-table adaptive radiation therapy (MRgRT) workflows, electron density of the target and organs-at-risk are obtained by deforming a simulation CT scan to the current MR setup scan. CT acquisition adds significant time to MRgRT workflows and imaging dose to the patient. Registrations have inherent limitations, particularly for air and tissue overriding, which frequently require manual corrections. We hypothesize that synthetically generated CTs (SynCTs) via deep learning could be utilized to accurately predict electron density directly from the MR setup scan for subsequent adaptive planning and dose computation. <h3>Materials/Methods</h3> Simulation MR/CT scans from 20 patients undergoing MRgRT were used to train a generative encoder-decoder network that predicts SynCTs from MR setup scans. All patients underwent a standard CT simulation followed by an MR simulation scan on the MR-Linac approximately 1 hour later. The trained network then predicted electron density for a different setup scan acquired at subsequent treatment fractions. These SynCT volumes were directly compared to the deformed CT volumes using mean absolute error in Hounsfield units (HU). SynCT volumes were also exported as DICOM sequences and re-imported to the MR-Linac treatment planning system to recalculate dose and assess differences in resulting dose distributions, dose volume histograms and clinical dose prescriptions. <h3>Results</h3> The trained network achieved good accuracy on both training and testing datasets (mean absolute error in HU ± standard deviation, train: 38.4 ± 19.1 HU, test: 45.9 ± 24.5 HU). Average time required to generate a SynCT for a single MR volume using the trained model was 0.63 ± 0.06 seconds. Using the SynCT volumes for dose re-optimization did not result in any clinically meaningful differences in doses calculated to the primary treatment volumes in all 20 plans. <h3>Conclusion</h3> Accuracy of deep learning based synthetic CT generation using low-field MR setup scans on MR-Linacs was sufficient for accurate dose calculation/optimization. This approach can enable MR-only treatment planning workflows on MR-Linacs, thereby increasing the efficiency of simulation and adaptive planning for MRgRT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.