Abstract

Abstract Aerobic sludge from a municipal activated sludge treatment plant, sludge from a conventional municipal anaerobic digester, aerobic sludge from an activated sludge process of a petroleum refinery, and granular sludge from an upflow sludge blanket reactor (USBR) were tested in the deemulsification of a water-in-oil emulsion. All sludges except the last one, showed a good deemulsification capability and could he used for a partial deemulsification of such emulsions. The rate and degree of the deemulsifications increased with an increase in sludge concentrations. The deemulsifications were faster at 85°C and required smaller amounts of sludge than in the case of the deemulsifications at room temperature. An extended stirring (up to a certain limit) in the course of the dispersion of sludge emulsion helped the deemulsification. Too vigorous agitation had an adverse effect. The deemulsification effect of sludge became less visible with an increase in the dilution of emulsion which caused an increase in its spontaneous deemulsification.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.