Abstract

A retrospective chart review. The aim of this study was to evaluate the screw accuracy of thoracic pedicle screws placed with a robot-guided navigation system. Thoracic pedicles are smaller in diameter than lumbar pedicles, making pedicle screw placement difficult. Misplaced pedicle screws may present complications including decreased construct stability, and increased risks of neurological deficits and blood vessel perforation. There is a dearth of knowledge on thoracic pedicle screw accuracy placed with a robot. A retrospective analysis of the robot-assisted placement of thoracic pedicle screws was performed. Preoperative and postoperative computed tomography (CT) scans of the implanted thoracic screws were collected to assess screw placement accuracy, pedicle breadth, and placement deviations. A CT-based Gertzbein and Robbins System was used to classify pedicle screw accuracy in 2mm increments. A custom image overlay software was used to determine the deviations between the preoperatively planned trajectory of pedicle screws and final placement at screw entry (tail), and tip in addition to the angular deviation. Seventy-five thoracic pedicle screws were implanted by navigated robotic guidance in 17 patients, only 1.3% (1/75) were repositioned intraoperatively. Average patient age and body mass index were 57.5 years and 25.9kg/m 2 , respectively, with 52.9% female patients. Surgery diagnoses were degenerative disk disease (47.1%) and adjacent segment disease (17.6%). There were zero complications, with no returns to the operating room. According to the CT-based Gertzbein and Robbins pedicle screw breach classification system, 93.3% (70/75) screws were grade A or B, 6.6% (5/75) were grade C, and 0% were grade D or E. The average deviation from the preoperative plan to actual final placement was 1.8±1.3mm for the screw tip, 1.6±0.9mm for the tail, and 2.1±1.5 degrees of angulation. The current investigation found a 93.3% accuracy of pedicle screw placement in the thoracic spine. Navigated robot assistance is a useful system for placing screws in the smaller pedicles of the thoracic spine. Level III-retrospective nonexperimental study.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.