Abstract

Abstract A pilot plant for removal of radioactivity from solutions has been built and tested. In an initial trial, uranium remaining in a Davies-Gray-analysis waste-solution was reduced 300,000-fold to 0.2 ppb by passing the solution through DiphonixTH ion-exchange columns. The columns were regenerated (and the uranium was recovered) with HEDPA (1-hydroxyethane-1,1-diphosphonic acid). The latter was destroyed with H2O2, and the uranium was reduced and precipitated as a phosphate. Final purification of the dissolved precipitate employed a U/TEVA·SpecTH (dipentyl pentylphosphonate) extraction chromatographic column. Studies of matrix effects upon the uptake of uranium by the DiphonixTH led to an initial dilution of the waste solution and to a reduction of ferric ion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.