Abstract

ABSTRACT Decomposition of two typical volatile organic compounds (VOCs): toluene and methyl ethyl ketone (MEK), was investigated by introducing the complete energy yield (i.e. amount of VOCs totally converted to CO and CO2 for every 1 kWh of electrical usage) and specific energy density (SED) for the non-thermal plasma technology. Three dielectric barrier discharge reactors of which SED range was 55 J/L to 283 J/L at a flow rate of 1 L/min were connected in a 3-reactor arranged in series using interconnecting tubes in the inlets and outlets. As a result of the serial reactor design, the energy efficiency of the system improved, and in particular, 7% of increase was found in at the same level of energy consumption. The mixed phase of VOCs (toluene and MEK) showed MEK as a limiting species in this study. As the inlet concentration rose from 20 to 100 ppmv, both energy yield and complete energy yield increased from 0.8 to 9.2 g/kWh and from 0.8 to 2.3 g/kWh, respectively.