AbstractIn this study, the decolorization of Levafix Brilliant Blue E‐B by electrocoagulation method using aluminum and iron electrodes was investigated. The influence of the operating variables such as current density, initial pH, time of electrolysis, supporting electrolyte concentration on decolorization efficiency, and energy consumption was determined. The results show that aluminum electrode (Al) was more effective than iron (Fe) electrode in terms of decolorization efficiencies and operating costs. When the aluminum electrode was used, 99% decolorization was obtained at current density of 100 A/m2, initial pH of 5.5, electrolyte concentration of 5 mM, and electrolysis time of 20 min. The corresponding energy consumption and operating cost were found as 16.9 kWh/m3 and 2.921 $ per m3, respectively. © 2010 American Institute of Chemical Engineers Environ Prog, 2011

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.