Abstract
When an anion-exchange resin column (Plasorba BR-350) was used for the treatment of unconjugated hyperbilirubinemia, we found an unexpected decrease in plasma retinol (vitamin A) concentrations in a patient with type I Crigler-Najjar syndrome. The purpose of our study was to investigate the mechanism of this decrease in plasma retinol. When the patient's serum bilirubin exceeded the bilirubin binding capacity of 14.7 mumol bilirubin/g serum albumin (i.e., 720 mumol/L of bilirubin), abrupt deterioration of the patient's neurologic status (suppression in his gait and speech) occurred, so the need to apply plasmapheresis to reduce the unconjugated bilirubin was indicated. Blood was drawn from the radial artery at a flow rate of 160 mL/min and pumped into a membrane plasma separator at a rate of 40 mL/min. The plasma was passed through the bilirubin adsorbent column and returned to the venous blood line of the plasma separator. Plasma samples were taken at the inlet and outlet of the bilirubin adsorbent column before and after treatment. The concentration of unconjugated bilirubin in plasma was effectively reduced by the perfusion, but plasma retinol was coincidentally decreased by the perfusion to vitamin A deficiency levels. The patient's plasma retinol was 2,127 nmol/L at the beginning of therapy and decreased to 1,492 nmol/L after repeated adsorption treatments. As the amounts of decrease in retinol (912 +/- 123 nmol/L) after the perfusion were almost equal to those in retinol-binding protein (1,010 +/- 192 nmol/L), retinol may have been removed as a form of holo retinol-binding protein. Decreases in retinol and retinol-binding protein levels were also observed in low-density lipoprotein (LDL) apheresis with a dextran sulfate column (i.e., a cation-exchange resin column). In the patient with Crigler-Najjar syndrome, retinol taken dietarily was removed by plasmapheresis. However, the patient manifested no clinical symptoms associated with vitamin A deficiency, since his liver storage of retinol could supply the loss caused by plasmapheresis treatment. We should measure plasma retinol concentrations to evaluate the loss of retinol during plasmapheresis treatment coupled with an anion-exchange resin column.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.