Abstract
The use of the pull-off test to evaluate the interfacial bond strength between substrate concrete and bonded materials can result in failure of the concrete substrate without clear indication of the interfacial bond strength. Proper knowledge of the interfacial bond strength between a repair material and concrete substrate is critical for the selection of repair materials and for the modeling of the performance of the composite section. This includes ultra-high performance concrete (UHPC) used for thin bonded overlays of concrete bridge decks. The bond strength of UHPC to concrete substrate sections was evaluated in this study using the pull-off test, a modified version of the pull-off test, and the modified splitting tensile strength test. The results identified some challenges with respect to the characterization of interfacial bond and associated variability of test results. A new test method proposed to determine the interfacial bond strength showed that bond strength can range between 2.3 and 3.5 MPa and low coefficient of variation of 1.4% and 3.4%, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.