Abstract

Coal fired-power plant has waste heat from exhaust de-aerator. Changes in coal-fired steam power plant operation cause change in deaerator temperature. The operating of coal-fired steam power plant about 150-300MW. Exhaust de-aerator temperature about 145°-170°C. The thermal energy can be recovered as electricity by using TEG. TEG is thermoelectric generator, an equipment which can convert heat flux to electric energy. TEG convert heat different between hot side and cold side. Dimension 1 Module of TEG is only 56x56x4 mm. The difference deaerator temperature influence TEG’s performance. TEG highest voltage and power output is 2.48V and 5.1W obtained. Developing coolling system and MPPT is needed to maximize TEG performance.