Abstract

BackgroundDespite the effectiveness of implantable cardioverter defibrillators (ICDs) in the prevention of sudden cardiac death, shock therapy causes patients to experience pain and psychological distress, which contradicts the purpose of palliative care. It is difficult to predict the time course for heart failure (HF) patients, unlike that for cancer patients. The aim of this study was to evaluate the deactivation status of ICD therapy in Japanese patients with end‐stage HF.MethodsWe retrospectively studied 51 ICD patients who died due to worsening HF at Tokyo Women's Medical University Hospital from 2010 to 2019. The frequency of ICD therapy delivered before death and information about the discussion of deactivation and do not attempt resuscitation (DNAR) decisions were reviewed using medical charts.ResultsOf 51 patients, 12 (24%) patients deactivated ICD therapy and seven patients underwent deactivation within 24 hours of a DNAR order. The median time from deactivation to death was 3 days (range, 0‐56). Of 39 patients with DNAR orders, 27 (69%) did not undergo deactivation. A relatively high proportion of patients (n = 14, 27%) experienced ICD shocks within 1 month of death. The frequency of electrical storms within 1 month of death was also high (n = 12, 24%).ConclusionsOur study showed that only one‐fourth of Japanese patients with end‐stage HF underwent deactivation of ICD therapy. A relatively high frequency of shock therapy was observed in the last month before death.