dc breakdown and corona inception voltages are reported for SF6-air and SF6-CO2 mixtures in positive and negative rod-plane gaps. These voltages are compared with values obtained for SF6-N2 mixtures. The results show that the breakdown voltages of SF6-air mixtures exhibit corona stabilization over a pressure range which depends upon SF6 content of these mixtures, and is higher than the corresponding values for SF6-N2 and SF6-CO2 mixtures. Moreover, a simple method to estimate the corona-stabilized breakdown voltages of SF6-gas mixtures is discussed. It is shown that at low pressures, this method gives estimated voltages which are generally in reasonable agreement with the experimental measurements of several authors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.