Abstract
Under certain working conditions, the permanent magnet synchronous motor (PMSM) traction system of urban rail transit shows negative impedance characteristics, which is easy to cause voltage resonance of DC-link and lead to instability of the system. In order to ensure the stability of the system, a DC-link oscillation suppression method based on q-axis voltage compensation is proposed. Firstly, the PMSM traction system and oscillation mechanism of DC-link are analyzed. Secondly, a stable control method based on q-axis feedforward decoupling voltage compensation is adopted to realize the decoupling control of PMSM and the suppression of DC-link oscillation. Finally, the method is verified on a 180 kW PMSM traction system, simulation and experiment verify the effectiveness of the DC-link oscillation suppression method.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.