Direct-current electrical discharges in seeded and unseeded propane-air flames have been studied for currents between 1 and 10 A. Two types of discharge were observed. At low currents and high seed concentrations the discharge occupies about half of the flame volume and is at a relatively low temperature. At higher currents the discharge contracts to about one third of its previous diameter into a high-temperature arc, which can be maintained without seed. The electrical characteristics of the two discharges are similar. Transition between the two arc modes is accompanied by a large change in anode fall voltage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.