Abstract

This paper deals with the breakdown voltage characteristics of saturated liquid helium in the presence of a needle-shaped or spherical metallic particle to obtain insulation design data for pool-cooled, low-temperature superconducting coils and to find the predominant factor affecting the breakdown voltage of liquid helium at a given state. The results show the following. (1) The generation of bubbles at the instant of collision of a particle with an electrode is caused mainly by the kinetic energy released from the moving particle to the liquid helium, while the electrostatic energy accompanying the microdischarge between the particle and the electrode has a lesser effect on it. (2) The lowest breakdown voltage at different particle conditions appears in the case of a free needle particle. The low breakdown voltage is caused by the bubble triggered by the particle collision, the high electric field at the tip of the needle particle, and the rich initial electrons supplied by the microdischarge

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call