Abstract

Objective: Ambulatory blood pressure (BP) monitors (ABPM) measure systolic and diastolic BP (SBP, DBP), limited to 24-48-hour snapshots, using uncomfortable cuff-based oscillometric sphygmomanometers. Some cuffless BP devices overcome these limitations, supporting continual BP monitoring. However, there is intense debate whether cuffless devices generate data comparable to ABPM. Here, we present preliminary results of daytime BP measurements performed by Aktiia cuffless BP monitor (Aktiia SA, Switzerland) compared to 24-hour ABPM. Design and method: 52 out of 63 estimated total patients (NCT04548986, age 53.2±7.1 years, 18.9% female, arm circumference 28.5±2 cm) had been enrolled in a 12-week cardiac rehabilitation (CR) program (Réseau Hospitalier Neuchâtelois, Switzerland). The patients used the Aktiia monitor during the entire CR program, while 24-hour ABPM (Dyasis 3, Novacor, France) was performed on the first and last day of the CR program. For each patient, average daytime (9am-9pm) SBP and DBP were calculated – and compared – for 1 day of ABPM and 7 days of Aktiia monitor (session 1: ABPM first day vs. Aktiia first week; session 2: ABPM last day vs. Aktiia last week). Only sessions that had 20 or more valid daytime measurements on both modalities were included in the study. Results: 50 patients (35 in session 1, 15 in session 2) had 20 or more valid daytime measurements on both modalities, and were included in the study. Bias between Aktiia monitor and ABPM for daytime DBP was (mean ± SD [95% CI]) -2.2±8.0 [-4.5, 0.1] mmHg (Figure 1A), with agreements of 78% and 96% within ±10 mmHg (dark grey) and ±15 mmHg (light grey) regions of interest (ROI), respectively. Bias between Aktiia monitor and ABPM for daytime SBP was 1.6±10.5 [-1.5, 4.6] mmHg (Figure 1B), with agreements of 60% and 84% within the ±10/±15 mmHg ROI, respectively. Conclusions: The results suggest that 1-week Aktiia monitor yields equivalent daytime BP values to 24-h ABPM, which supports the use of Aktiia monitor for long-term, continual daytime BP monitoring. The present preliminary study is limited by the partially recruited population and daytime measurements only. Night-time analysis will be covered in subsequent studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.