Abstract

According to World Health Organization guidelines, corrosion control is an important aspect of safe drinking-water supplies. The data presented is physical and chemical parameters of drinking water in the rural areas of Torbat-e-Heydariyeh city, also to determine corrosion indices. This cross-sectional study has carried out with 188 taken samples during 2014 with 13 parameters, which has been analyzed based on standard method. Also with regard to standard conditions, result of this paper is compared with Environmental Protection Agency and Iran national standards. Five indices, Langlier Saturation Index (LSI), Ryznar Stability Index (RSI), Puckorius Scaling Index (PSI), Larson-Skold Index (LS) and Aggressive Index (AI), programmed by using Microsoft Excel software. Owing to its simplicity, the program can easily be used by researchers and operators. Parameters included Sulfate, Sodium, Chloride, and Electrical Conductivity respectively was 13.5%, 28%, 10.5%, and 15% more than standard level. The amounts of Nitrate, in 98% of cases were in permissible limits and about 2% were more than standard level. Result of presented research indicate that water is corrosive at 10.6%, 89.4%, 87.2%, 59.6% and 14.9% of drinking water supply reservoirs, according to LSI, RSI, PSI, LS and AI, respectively.

Highlights

  • Stability index which has been analyzed based on standard method

  • Experiments conducted in two general categories of device experiments and Titration

  • Determination of the physical and chemical parameter including EC, TDS, TH, CaH, pH, Turbidity, Cl, NO3, SO42, F, Na þ TDS, Ca2 þ, Mg2 þ, in ground water was investigated in rural area, Khorasan-e-Razavi province, Iran

Read more

Summary

Data accessibility

Titration Experiment includes temporary and permanent hardness, magnesium, calcium and chloride, Device. Titration Experiment includes temporary and permanent hardness, magnesium, calcium and chlorides, Device Experiment consist of pH, Electrical conductivity, Turbidity, Fluorine, nitrate, sulfate. Determination of the physical and chemical parameter including EC, TDS, TH, CaH, pH, Turbidity, Cl , NO3 , SO42 , F, Na þ TDS, Ca2 þ , Mg2 þ , in ground water was investigated in rural area, Khorasan-e-Razavi province, Iran. Data presented here deal with monitoring of physical and chemical including EC, TDS, TH, CaH, pH, Turbidity, Cl, NO3 , SO42 , F, Na þ TDS, Ca and Mg As in Khorasan-e-Razavi province, Iran. 2014, Table 3 shows comparison drinking water resources in the rural area of Torbat-e-Heydarie in. 2014, Table 4 shows calculation of water stability indices at sampling temperature

Study area description
Findings
Materials and methods