Abstract

BackgroundMobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. However, physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inherently introduces new challenges. Thus far, no methodology exists to systematically evaluate these implementation challenges and identify the related risks.ObjectiveThis study aimed to facilitate the implementation of mHealth initiatives with mobile physiological sensing in constrained health systems by developing a methodology to systematically evaluate potential challenges and implementation risks.MethodsWe performed a quantitative analysis of physiological data obtained from a randomized household intervention trial that implemented sensor-based mHealth tools (pulse oximetry combined with a respiratory rate assessment app) to monitor health outcomes of 317 children (aged 6-36 months) that were visited weekly by 1 of 9 field workers in a rural Peruvian setting. The analysis focused on data integrity such as data completeness and signal quality. In addition, we performed a qualitative analysis of pretrial usability and semistructured posttrial interviews with a subset of app users (7 field workers and 7 health care center staff members) focusing on data integrity and reasons for loss thereof. Common themes were identified using a content analysis approach. Risk factors of each theme were detailed and then generalized and expanded into a checklist by reviewing 8 mHealth projects from the literature. An expert panel evaluated the checklist during 2 iterations until agreement between the 5 experts was achieved.ResultsPulse oximetry signals were recorded in 78.36% (12,098/15,439) of subject visits where tablets were used. Signal quality decreased for 1 and increased for 7 field workers over time (1 excluded). Usability issues were addressed and the workflow was improved. Users considered the app easy and logical to use. In the qualitative analysis, we constructed a thematic map with the causes of low data integrity. We sorted them into 5 main challenge categories: environment, technology, user skills, user motivation, and subject engagement. The obtained categories were translated into detailed risk factors and presented in the form of an actionable checklist to evaluate possible implementation risks. By visually inspecting the checklist, open issues and sources for potential risks can be easily identified.ConclusionsWe developed a data integrity–based methodology to assess the potential challenges and risks of sensor-based mHealth projects. Aiming at improving data integrity, implementers can focus on the evaluation of environment, technology, user skills, user motivation, and subject engagement challenges. We provide a checklist to assist mHealth implementers with a structured evaluation protocol when planning and preparing projects.

Highlights

  • BackgroundLimited access to adequate health care is a major burden in lowand middle-income countries and affects the poor most [1]

  • We performed a quantitative analysis of physiological data obtained from a randomized household intervention trial that implemented sensor-based Mobile health (mHealth) tools to monitor health outcomes of 317 children that were visited weekly by 1 of 9 field workers in a rural Peruvian setting

  • After the analysis of the data integrity gaps in the recorded data, we identified possible causes that could have led to these gaps from both the paper-based trial case report forms (CRFs) and through qualitative data obtained from posttrial semistructured interviews with the app users conducted on site after the trial

Read more

Summary

Introduction

BackgroundLimited access to adequate health care is a major burden in lowand middle-income countries and affects the poor most [1]. Mobile health (mHealth) is a promising field that seeks to bring health care closer to the patient, thereby improving access and reducing costs because of its potential for a system-wide application [3]. Biomedical sensing using connected mobile sensors is an important but largely unexplored application in mHealth. It provides objective measurement of physiological parameters and facilitates more reliable diagnoses and assessments of patients. Mobile health (mHealth) technologies have the potential to bring health care closer to people with otherwise limited access to adequate health care. Physiological monitoring using mobile medical sensors is not yet widely used as adding biomedical sensors to mHealth projects inherently introduces new challenges. No methodology exists to systematically evaluate these implementation challenges and identify the related risks

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call