Abstract

Ultrasonic flowmeters have potential for wide application in natural gas and hydrogen flow measurements in China. Accurate measurement is essential; thus, data fusion of acoustic paths is of importance. A data integration method for multi-path flowmeter measurement is introduced and investigated in this study. The novel data integration method is based on the Levenberg–Marquardt algorithm. Computational fluid dynamics has been used to simulate the flows, and a laboratory scale system was established to obtain experimental measurements. The results of the simulations and experiments reveal that the method is able to reduce measurement error compared with four traditional integration methods in flow-rate measuring in a long straight pipe. Furthermore, both the simulation and experiment results validate the integration method for non-ideal flow conditions, such as flow downstream a single elbow or a 180° bend. The relative errors are within 1%, instead of more than 2%, which is typical for traditional methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.