Abstract

Neutron diagnostic “Divertor Neutron Flux Monitor” is being under the development for the ITER project. This diagnostic is a primary tool for total neutron yield and fusion power measurements. Diagnostic consists of the three detector modules and the enhanced data acquisition (DAQ) systems. Each module contains three fission chambers (FCs) with 235U and three with 238U. The choice of the FC types and sensitivities is determined by the project requirements for the neutron flux measurement range, error, and time resolution. The DAQ system performs preliminary amplification and processing of the fission chamber signals, and the calculation of the neutron flux at the module location to calculate the total neutron yield and fusion power. The DAQ system transfers measured data to the upper level of the control system with a time resolution of 1 ms and provides raw data archiving. The hardware and software of the DAQ system were developed taking into account the requirements of the ITER project. The data processing system mockup of a single detection module was manufactured. This mockup passed laboratory and reactor tests. The system has passed the preliminary design approval. Preparation for the manufacturing of the system prototype is carried out at this moment. The architecture of the DAQ system and its components are shown in the report, and the test results of the system mockup are discussed.

Highlights

  • The data acquisition system (DAQ) is a part of the Divertor Neutron Flux Monitor (DNFM) diagnostic

  • The DNFM diagnostic used three detector modules located around the ITER Vacuum Vessel through 120 degrees

  • Each DNFM detector module consists of two detector units (DU) and each detector unit consists of three fission chambers

Read more

Summary

Introduction

The data acquisition system (DAQ) is a part of the DNFM diagnostic. This system is designed for signal processing of the three neutron detectors modules, each including six fission chambers (FC). Data Acquisition System for ITER Neutron Diagnostic Divertor The ITER nuclear diagnostics Divertor Neutron Flux Monitor (DNFM) is designed to determine the ITER fusion power.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.