Abstract

The dynamic range of X-ray detectors is a key factor limiting both the spatial resolution and sensitivity of X-ray ptychography as well as the coherent flux of incident X-rays. Here, we propose a method for high-resolution and high-sensitivity X-ray ptychography named "dark-field X-ray ptychography", which compresses the dynamic range of intensities of diffraction patterns. In this method, a small reference object is aligned upstream of the sample. The scattered X-rays from the object work as a reference beam for in-line holography. Ptychographic diffraction patterns including the in-line hologram are collected, and then the image of the sample is reconstructed by an iterative phasing method. This method allows us to obscure the low-Q region of the diffraction patterns using a beamstop since the in-line hologram complements structural information in the low-Q region, resulting in the compression of the dynamic range of intensities of diffraction patterns. A numerical study shows that the dynamic range of intensities of diffraction patterns is decreased by about three orders of magnitude.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.