Abstract
The damaged depths in GaAs processed by Ar plasma etching under various applied radio-frequency (RF) voltages and Ar pressures in a parallel-plate type apparatus were studied. The damaged depth was evaluated in terms of the chemically etched thickness at which the photoluminescence intensity recovers. The damaged depth decreased as the applied radio frequency peak voltage was decreased. The depth was extraordinarily deep in the lower radio frequency voltage region. The effect of Ar pressure on damaged depth was small in the range from 1 to 10 Pa.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.