Abstract

JET has operated with beryllium limiters such that up to 180 MJ could be coupled to the plasma. Approximately 2–4% of the surface of the limiter has been melted near the plasma contact point. Another 10–15% of the surface shows evidence of edge heating. Some 5% of tiles have been subjected to abnormal loads at points distant from the contact area. Damage shows strong correlation of localised heating of the limiter with toroidal field ripple. Edge heating rates of 260 Mw/m 2 have not caused gross mechanical failure of the limiter. The mechanical damage comprises fatigue cracks analogous to those due to sustained loading at low power levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.