Abstract

In this work, damage results of four 12 mm × 12 mm × 5 mm PLANSEE double forged tungsten target samples exposed in INTI PF device at different distances from anode operating in the fast focus mode at 12 kV, 2.5 Torr deuterium are presented. SEM and EDX images and analysis show the extent of damage on the exposed tungsten surface. Micro-cracks up to 300 nm and 500 nm to 5 μm holes together with signs of melting are found on the tungsten exposed surfaces depending on their distances from the anode top. Current waveforms fitting using Lee Model Code show yields of 3 × 106 neutrons and 8.5 × 1014 ions per shot with average ion energy of 56 keV per ion at pinch exit, generating heat flux of 1.8 × 1014 Wm−2 and damage factor (also called heat flux factor) of 1.6 × 1010 Wm−2s0.5 on a target at pinch exit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.